Running a successful restaurant requires more than just great food and serviceit also depends on having the right equipment.

Running a successful restaurant requires more than just great food and serviceit also depends on having the right equipment.

Running a successful restaurant requires more than just great food and serviceit also depends on having the right equipment.

Our company is an integrated enterprise specializing in the R&D, production, sales, and service of tea beverage equipment. Established in 2006 and headquartered in Shanghai, we have our own factories in both Shanghai and Guangdong. With a professional R&D team, we can meet the customized requirements, continuously striving for innovation, intelligent manufacturing, and quality leadership

Running a successful restaurant requires more than just great food and serviceit also depends on having the right equipment.

Product parameters

Product Model

NS-782G

Rated voltage

220V/50Hz

Rated voltage

220V/50Hz

Heating power

3000W

Boiler capacity

8.5L

Net weight

23kg

Dimensions

L285*W466*H552mm

Usage

Dual Heating

Product Benefits

Product Features

Anti-siphon

The anti-siphon feature in milk steamers is a vital safety function that prevents liquid backflow. It uses a special valve or steam line design to maintain positive internal pressure after steam stops. This instantly blocks the vacuum effect, preventing milk or water from being sucked back into the system. By stopping contaminants from entering the boiler, it eliminates cross-contamination between drinks and protects internal components from clogging and corrosion caused by milk residue. This ensures operational hygiene, maintains consistent steam performance, and reduces long-term maintenance needs.

High-Capacity Boiler

The large-capacity boiler in commercial milk steamers maintains exceptional thermal stability for continuous high-demand operation. Its substantial water volume ensures consistent steam pressure and temperature, enabling rapid microfoam production without pressure fluctuations. This design reduces frequent heater cycling, decreasing energy consumption and mechanical stress on components. By minimizing thermal strain, it significantly extends the lifespan of heating elements and pressure systems while ensuring reliable performance during peak service. This engineering guarantees beverage consistency, enhances equipment durability, and lowers operating costs in busy commercial environments.

Self-priming

Professional milk steamers feature pressurized water systems that maintain constant pressure through high-performance pumps, enabling instant steam generation and rapid boiler refilling. This eliminates pressure fluctuations during continuous operation, ensuring consistent steam texture and optimal dryness for perfect microfoam. The system enhances workflow efficiency while protecting heating elements from dry-fire risks through integrated monitoring. This pressure management technology is vital for high-volume operations where steam reliability directly determines beverage quality and service capacity.

PID Temperature Control

Milk steamers with PID temperature control maintain ±0.5°C precision to accurately target the 55-65°C range where lactose sweetness optimally develops without protein scalding. This system ensures consistent microfoam texture while preventing temperature overshoot through real-time thermal compensation. Suitable for both dairy and plant-based alternatives, it guarantees ideal viscosity and complete flavor extraction across all beverage types. The precise thermal management significantly reduces milk waste through predictable results, making it indispensable for specialty coffee where temperature accuracy directly determines the final sensory experience and customer satisfaction.

Water Level Alarm

The water level alert system in milk steamers employs precision sensors to monitor boiler volume. When detecting low water conditions, it activates visual and audible alarms while automatically cutting power to heating elements to prevent dry-fire damage. This protective mechanism safeguards critical components from overheating failures. With self-diagnostic capabilities to differentiate actual low water from sensor errors, it ensures operational reliability. This maintenance feature reduces downtime, extends equipment lifespan, and maintains workflow continuity through timely refill reminders in commercial environments.

Water Level Alarm

The CE certification on milk steamers confirms compliance with EU safety regulations including machinery directives, EMC standards, and electrical safety requirements. This verification ensures the appliance incorporates critical protection systems such as reinforced insulation, proper grounding, overload prevention, and fire-resistant materials while maintaining electromagnetic emissions within EN 55014 limits. As a mandatory requirement for European Economic Area market access, this certification reduces commercial operational risks while enhancing the manufacturer’s credibility and competitive edge in the global professional coffee equipment industry.